The RoseCup provides volume control of your meal when used with the Soft Spout attachments. This occurs because you need to suck on the soft spout to release the liquid. Each time you do this only a limited amount of liquid is released into your mouth. This function prevents a continuous flow of liquid, allowing you to control the amount of fluid you take each time - reducing the risk of choking.
How does it work? The spouts have been designed to hold 3ml of thickened fluid within the spout bulb. When the bulb is compressed, the base is blocked by the tip of the tongue allowing only the content of the bulb to be delivered onto the tongue. The valve closes after the suck-cycle (restores to “hole-only” state) and no further liquid should escape from the device.
The controlled delivery limits the volume of liquid per suck-cycle to 3ml. A further suck cycle is required before another bolus is released, interrupting continuous flow and allowing successive deliveries to be paced. This design is intended to support better coordination of liquid intake and airway protection.
It is recommended that you regularly check your soft spout is working correctly before use. This can also be monitored by a carer.
When used with the Soft Spout attachments the RoseCup assists with the process of swallowing your thickened liquid meal.
How does it do this? Active sucking stimulates a coordinated sequence of oral movements involved in liquid collection, bolus formation and transfer. Infant feeding demonstrates how sucking, bolus formation and swallowing can operate as a closely coordinated sequence. This physiological observation informed the development of the RoseCup's suck‑based delivery system; it is not presented as evidence that infant and adult dysphagia physiology are identical.
If the swallowing mechanism in Dysphagia is initiated by the suck reflex, we suspect that swallowing will likely be more effective and complete than with traditional feeding methods. Suck-initiated delivery may assist bolus formation and transfer while limiting uncontrolled pharyngeal delivery.


You can use the RoseCup with any of the three types of attachments (Spoon, Sipper or Soft Spout) while using thickened liquids.
The RoseCup system is developed in Australia and protected by granted patents in multiple international jurisdictions to assist in the management of Dysphagia. It does support feeding and swallowing in general. The RoseCup® is named in the honour of Rose Palmada whose predicament directly led to the discovery of the principles of feeding built into the RoseCup.

We recommend using the following attachments with your RoseCup, while in a seated position.

We recommend using the following attachments with your RoseCup, while in a reclined position.


-- / 5 average rating from -- reviews
We'd love to hear your thoughts!
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Suspendisse varius enim in eros elementum tristique. Duis cursus, mi quis viverra ornare, eros dolor interdum nulla, ut commodo diam libero vitae erat. Aenean faucibus nibh et justo cursus id rutrum lorem imperdiet. Nunc ut sem vitae risus tristique posuere.
We'd love to hear your thoughts!
-- / 5 average rating from -- reviews
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Suspendisse varius enim in eros elementum tristique. Duis cursus, mi quis viverra ornare, eros dolor interdum nulla, ut commodo diam libero vitae erat. Aenean faucibus nibh et justo cursus id rutrum lorem imperdiet. Nunc ut sem vitae risus tristique posuere. uis cursus, mi quis viverra ornare, eros dolor interdum nulla, ut commodo diam libero vitae era